Product description
The Sulfimax GX online WATER continuously, rapidly, and precisely measures hydrogen sulfide (H2S) and sulfides in wastewater and other aqueous samples. This enables timely, demand-driven interventions in process streams and wastewater treatment operations.
Effective gas extraction ensures the complete removal of H2S from the sample, while matrix-related interferences are almost entirely eliminated. The released H2S gas is transferred to a highly sensitive sensor capable of detecting concentrations from 0.01 to 1,000 ppm.
Typical measurement times range from 5 to 15 minutes, depending on sample composition.
With the Sulfimax GX online WATER, even challenging industrial wastewaters contaminated with hydrocarbons or ammonia, or exhibiting basic pH values, can be monitored reliably and reproducibly.
Sample aspiration, all rinsing steps, and return to the pipeline system are performed fully automatically. Configuration adjustments and data retrieval are possible via remote access, and measurement results can be transmitted to on-site alarm systems via digital and analog outputs.
Key Features:
- Continuous monitoring of H2S and sulfides in aqueous samples
- Effective gas extraction for high measurement accuracy
- Wide measuring range: 0.01 to 1,000 ppm
- Reliable monitoring of contaminated industrial wastewater
- Fully automated sampling, rinsing, and reintegration
- Remote access for configuration and data retrieval
- Digital and analog outputs for alarm system integration
This device complies with the following standards
The Sulfimax GX online WATER as ATEX compliant version is suitable for use in ATEX zone 1 (gas) according to DIN EN IEC 60079-2.
Applications
- Online acquisition of the current sulphide concentration
Environmental analysis, e.g.
- Waste water analysis for control systems (pump sump, free level or pressure water pipe)
- Landfill leachate monitoring
- Industrial sewage treatment plants
- Municipal sewage treatment plants
Advantages
- Automatic sample dosing
- Hardly any cross-sensitivities due to indirect method
- Output 4 to 20 mA for integration of the H2S signal into the control system
- Short measuring intervals allow fast reaction to changes
- Low maintenance requirements
Features and Results
- Detection of the true H2S content directly in the liquid phase and thus independent of weather conditions (even in strongly basic samples)
- Simple calibration
- Simple, clear software
- No cross-contamination due to self-cleaning between measurements
- Long sensor life due to integrated regeneration processes
Note: The appearance of our products on this website may differ from the actual version due to ongoing product development.