Product description

The Aquamax KF PRO LPG fully complies with the requirements of ASTM D7995-19Standard Test Method for Total Water in Liquid Butane by Liquefied Gas Sampler and Coulometric Karl Fischer Titration.

Specifically developed for the simple and precise determination of water content in liquefied and gaseous samples such as LPG and LNG, the Aquamax KF PRO LPG combines the coulometric Karl Fischer method with a unique gas evaporation and dosing system.

Designed for Maximum Performance and Automation

The system includes all essential components for ppm-level water analysis in LPG and gases, including a sulfur removal cartridge that reliably eliminates side reactions caused by sulfides and H₂S.

Thanks to the innovative sample loop principle, fully automated operation is possible – with up to 125 measurements per day.

All components of the Aquamax KF PRO LPG are fully enclosed, ensuring maximum safety and durability, even under the demanding conditions of the petrochemical and petroleum industries.

The unique ECH sample loop design provides maximum flexibility:

  • Use as a fully automated laboratory instrument
  • Operation as a portable field analyzer
  • Or direct integration into the process as a powerful online monitoring system
Aquamax KF PRO LPG
Aquamax KF PRO LPG

Our instruments comply with the following standards:

ASTM D 1364, ASTM D 1533, ASTM D 3401, ASTM D 4928, ASTM D 6304, ASTM D 7995, ASTM E 1064, API Ch. 10.9, DIN 51777, DIN EN ISO 12937, EI /IP 386, EI / IP 438, IEC 60814, ISO TC 158/SC, ISO 10101-1, ISO 10101-3, ISO 10337

Applications

LPG, LNG:

  •  Propane, propene, butane, butene, butadiene
  •  Ethylene oxide
  •  Chlorinated hydrocarbons, e. g. methylene chloride, ethylene chloride, vinyl chloride

Analysis of refrigerants:

  •  Halogenated hydrocarbons

Analysis of permanent gases:

  •  Natural gas
  •  Technical gases
  •  Test gas mixtures

Advantages

  • Sulphur removal cartridge eliminating the side reactions caused by sulphides/H2S
  • No interference calculation required
  • Totally automated process, no operator input required for the test
  • 250 measurements can be performed in 48 hours
  • No balance is required
  • Suitable to test all gas types without any calibration or adjustments
  • Rinsing process is fully automated
  • High sample throughput and long reagent life
  • Compact device

Features and Results

  • Determination of moisture in liquefied and gaseous samples
  • Inlet pressure up to 200 bar/2900 psi
  • Determination of pressure in the sample loop
  • Automatic pressure regulation
  • Transfer line with direct injection
  • Automatic rinsing bypass and steps for rinsing
  • Measuring cell without diaphragm (only one electrolyte required)
  • Setting of application-specific methods
  • Sulphur trap eliminating the side reactions caused by sulphides/H2S
  • Type of result: µg, ppm (gas volume), Vppm, Mppm, Mol ppm by using the formula generator
Banner Bild 1 Banner Bild 2